TM 9-2350-238-20-1
Table 2-3. UNIT TROUBLESHOOTING (CONT)
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
Troubleshoot magnetic clutch and bypass solenoid valve circuit (HYD
Step 2.
PUMP/PTO CLUTCH switch). Refer to Electrical Circuit Symptom Index,
61. HYDRAULIC SYSTEM DOES NOT OPERATE WHILE ENGINE IS RUNNING AT 1350 RPM,
CLUTCH ENGAGED INDICATOR LIGHT IS ON, AND MASTER AND HYD PUMP/PTO
CLUTCH SWITCHES ARE ON.
Step 1.
Check magnetic clutch ground lead for bad connection.
Clean ground connections with crocus cloth (item 10, appx C). Tighten
ground connections.
Troubleshoot magnetic clutch and bypass solenoid valve circuit (magnetic
Step 2.
clutch). Refer to Electrical Circuit Symptom Index, page 2-92.
62. ENGINE SPEED WILL NOT HOLD 1350 RPM WHILE HYDRAULIC SYSTEM IS OPERATING,
CLUTCH ENGAGED INDICATOR LIGHT IS ON, AND MASTER AND HYD PUMP/PTO
CLUTCH SWITCHES ARE ON.
Check bypass solenoid valve ground lead for bad connection.
Step 1.
Clean ground connections with crocus cloth (item 10, appx C). Tighten
ground connections.
Troubleshoot magnetic clutch and bypass solenoid valve circuit (bypass
Step 2.
solenoid valve). Refer to Electrical Circuit Symptom Index, page 2-92.
ELECTRICAL--RADIO
63. CONSTANT CLICKING SOUND WHEN ENGINE IS OPERATING FASTER THAN IDLING
SPEED.
Check voltage regulator ground strap for bad connection.
Step 1.
Clean voltage regulator ground strap with crocus cloth (item 10, appx C).
Tighten ground connection.
If problem still exists, notify direct support maintenance.