Table 2-3. UNIT TROUBLESHOOTING (CONT)
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
ELECTRICAL--BATTERY POWER
14. MASTER IND LIGHT IS ON AND ELECTRICAL CIRCUITS ARE NOT OPERATING.
NOTE
Screws holding master relay on bulkhead also ground relay.
Check master relay ground for bad connection.
Step 1.
Clean ground connections with crocus cloth (item 10, appx C). Tighten
ground connections.
Troubleshoot master relay circuit. Refer to Electrical Circuit Symptom Index,
Step 2.
15. ELECTRICAL CIRCUITS ARE NOT OPERATING OR BATTERY-GENERATOR INDICATOR
IS IN RED (0-TO 22-VOLT RANGE).
If BATTERY-GENERATOR indicator light is in red, troubleshoot BATTERY-
Step 1.
GENERATOR indicator circuit. Refer to Electrical Circuit Symptom Index,
Check batteries with tester.
Step 2.
Charge batteries, refer to TM 9-6140-200-14; or replace batteries, refer
to page 2-92.
Troubleshoot battery power circuit. Refer to Electrical Circuit Symptom Index,
Step 3.
Troubleshoot master switch circuit. Refer to Electrical Circuit Symptom Index,
Step 4.