TM 9-2330-202-14&P
4-28.2. STOPLIGHT MAINTENANCE (M101A1 AND M116A1) (CONTINUED).
c.
STOPLIGHT DISASSEMBLY
1.
Push back three shells (19) and remove slotted washers (20) and shells off wire.
NOTE
Screws (1) are held in lens retainer (2) by retainers (3).
2.
Loosen six screws (1), remove lens retainer (2), and preformed packing (4). Discard preformed pack-
ing.
3.
Remove lamp (5) and two lamps (6) from sockets (7) by pushing in and turning counterclockwise.
4.
Remove two screws (21) and lockwashers (22). Discard lockwashers.
5.
Remove three screws (23) and pull socket and wiring assembly (24), retaining plate (25), and grom-
met (26) out of housing (27).
438-014
d.
CLEANING AND INSPECTION
WARNING
Drycleaning solvent P-D-680 is toxic and flammable. Always wear protective
goggles and gloves, and use only in a well-ventilated area. Avoid contact
with skin, eyes, and clothes, and DO NOT breathe vapors. DO NOT use near
open flame or excessive heat.
1.
Use drycleaning solvent to clean lens, lens retainer, and outside of housing. Dry thoroughly.
2.
Use detergent and water to clean inside of housing. Dry thoroughly.
3.
Use abrasive cloth to remove corrosion from lens retainer and housing.
4-42.8 Change 2
|