TM 9-2320-386-10
3-7. CHECKING FLUID LEVELS (Contd)
d. Front Winch Hydraulic Oil Reservoir Level.
CAUTION
Before opening hydraulic reservoir, ensure area around reservoir
filler cap is clean. Do not allow dirt, dust, or water to enter
reservoir. Failure to do this may cause damage to internal
components.
(1)
Check oil level through sight glass (6) on hydraulic oil reservoir (5).
(2)
If oil level is not seen in sight glass (6), remove cap (4) and add oil as
necessary (table 2-2). Fill hydraulic oil reservoir (5) until oil level is
centered in sight glass (6).
e. Master Cylinder Reservoir Oil Level.
WARNING
Clean master cylinder reservoir filler cap and surrounding area
before removing cap. System contamination may result in injury to
personnel or damage to equipment.
(1)
Remove two filler caps (7) from master cylinder reservoir (8).
(2)
Check that oil level is to bottom ring of opening.
(3)
Fill master cylinder reservoir (8) to bottom ring of opening as necessary
(4)
Install two filler caps (7) on master cylinder reservoir (8).
7
4
8
6
5
Change 1
3-23
|