TM 9-2320-386-10
2-48. OPERATION OF SWINGFIRE HEATER (Contd)
(7) Raise power receptacle cover (9) and install one end of starter cable (10) in
power receptacle (11). Install other end of starter cable (10) in starter cable
receptacle (14).
(8) Squeeze ignition switch (13) against pump lever (12) and hold there one
minute for every 10F (-12C) below 0F (-18C), then release.
NOTE
It may be necessary to loosen wingnut and open cover slightly so
pulsating sounds can be heard more clearly.
(9) Move pump lever (12) forward and backward three or four times, then
turn fuel regulator knob (2) one to one-and-a-half turns counterclockwise. Continue
moving pump lever (12) and adjust fuel regulator knob (2) until pulsating sounds
come to equal intervals.
(10) When pulsating sounds come to equal intervals, stop moving pump lever (12).
(11) Let swingfire heater (7) run three to five minutes. Adjust fuel regulator
knob (2) if pulsations are not at equal intervals.
(12) Close cover (1) if opened and tighten wingnut (6) by turning clockwise.
(13) Remove starter cable (10) from starter cable receptacle (14) and power
receptacle (11). Close power receptacle cover (9).
(14) Install swingfire heater (7) in mixing pipe (refer to task c.), turboheater
(refer to task d.), or water jacket (refer to task e.), as necessary.
2
13
9
12
10
11
7
10
6
14
2-113
|