TM 9-2320-386-10
Table 2-2. Operator/Crew Preventive Maintenance Checks and Services (Contd).
ITEM TO
NOT FULLY
ITEM
INTERVAL
CHECK/
PROCEDURE
MISSION
NO.
SERVICE
CAPABLE IF:
38
Weekly
Batteries
WARNING
Do not smoke, allow open
flames, or make sparks when
working near batteries.
Batteries may explode, causing
injury or death to personnel.
Remove all jewelry such as
rings, dog tags, bracelets, etc. If
jewelry contacts battery termi-
nal, a direct short may result in
instant heating of tools, dam-
age to equipment, and injury or
death to personnel.
a. Remove battery cell caps (5) to
check that fluid level is to split-rings.
NOTE
If fluid level is below split-
rings, or is boiling, notify unit
maintenance.
When temperature drops
below 32F (0C), run engine
15 minutes to allow water
added to battery by mainte-
nance personnel to mix with
electrolyte.
b. Check cables and posts (4) for
tightness, damage, and corrosion.
c. Visually check batteries (6) for
c. One or more
cracked or leaking casing, broken,
batteries are missing,
burnt, or corroded terminal posts (4).
leaking, unserviceable,
or will not crank
engine.