21-2. GAS PARTICULATE FILTER UNIT REPAIR (CONT)
g. Uncontaminated Filter Removal
WARNING
After Nuclear, Biological, or Chemical (NBC) exposure of vehicle, all air filters shall
be handled with extreme caution. Unprotected personnel may experience injury or
death if residual toxic agents or radioactive material are present. If vehicle is
exposed to chemical or biological agents, servicing personnel shall wear
protective mask, hood, protective overgarments, and chemical protective gloves
and boots in accordance with FM 3-4. All contaminated air filters shall be placed in
double-lined plastic bags and moved swiftly to a segregation area away from the
worksite. The same procedure applies for radioactive dust contamination. The
Company NBC team should measure radiation prior to filter removal to determine
extent of safety procedures required per the NBC Annex to the unit Standard
Operating Procedures (SOP). The segregation area in which the contaminated air
filters are temporarily stored shall be marked with appropriate NBC placards. Final
disposal of contaminated air filters shall be in accordance with local SOP.
Decontamination operation shall be in accordance with FM 3-5 and local SOP.
NOTE
Both filters are replaced the same
way.
(1) Loosen two clamps (1) on hoses (2 and
3).
(2) Remove two hoses (2 and 3) from filter
(4).
(3) Remove cap (4.1), nut (5), lockwasher (6),
bracket (7), screw (8), and filter (4) from
bracket (9). Discard lockwasher.
NOTE
If replacing bracket, do step (4).
(4) Remove four locknuts (10), screws (11),
and bracket (9) from side of cab (12) with
aid of assistant Discard locknuts.