2320-01-318-9902 EIC:B5C, VOLUME NO. 2">
|
|
TM 9-2320-360-20-2
21-2. GAS PARTICULATE FILTER UNIT REPAIR (CONT)
e. Tube Assembly
WARNING
Sealing compound can burn easily, can give off harmful vapors, and is harmful to
skin and clothing. To avoid injury or death, keep away from open fire and use in
well-ventilated area.
If sealing compound gets on skin or clothing, wash
immediately with soap and water.
NOTE
Ensure mating ends of tube are smooth (free from ridges and burrs).
Ensure mating ends of tubes fit properly before proceeding.
(1) Wipe mating ends of tubes with methyl ethyl ketone.
NOTE
Tubes must be installed before bonding cement dries.
If bonding cement dries before installation, apply a new coat.
(2) Apply thick coat of bonding cement to male end of tube.
(3) Apply thin coat of bonding cement to female end of tube.
(4) Twist male end of tube into female end until fully seated. Hold until set.
f. Air Hose, Pipe, and Bracket Installation
NOTE
If pipes were removed, do steps (1)
thru (5).
(1) Install two brackets (1) on cab wall (2) with
two screws (3).
21-8
|