21-2. GAS PARTICULATE FILTER UNIT REPAIR (CONT)
(5) Position precleaner (2) in frame (8) with
electrical plug (12) toward front of cab.
(6) Close clamp (13) on frame (8).
(7) Install two hoses (14) on precleaner (2)
with clamps (15).
(8) Install plug (12) in receptacle (16).
(9) Install receptacle (17) in precleaner (2).
(10) Convert beds to backseat (TM 9-2320-
360-10).
d. Air Hose, Pipe, and Bracket Removal
NOTE
All air hoses and brackets
are
replaced the same way.
(1) Loosen clamp (1) on air hose (2).
(2) Remove air hose (2) from pipe (3).
(3) Disconnect air hose (2) from
orifice
connector (4).
WARNING
Wear eye protection and use care
when removing retaining rings.
Retaining rings are under spring
tension and can act as projectiles
when released and may cause severe
eye injury.
(4) Remove retaining ring (5) and orifice
connector (4) from angle bracket (6).
Discard retaining ring.
(5) Remove screw (7), clip (8), and angle
bracket (6) from cab wall (9).
21-6 Change 2
|