2320-01-318-9902 EIC:B5C, VOLUME NO. 2">
|
|
TM 9-2320-360-20-2
(27) Disconnect plug (39) from socket (40).
(28) Remove STE/ICE water temperature
sender (41) from tee (42).
(29) Remove screw (43) and lockwasher (44)
from clip (45). Discard lockwasher.
(30) Remove elbow (38), reducer coupling (46)
and nipple (47) from tee (42).
(31) Remove tee (42) from engine block (31).
(32) Remove fitting (48) from tee (42).
b. Installation
WARNING
Pipe thread sealing compound can
burn easily, can give off harmful
vapors, and is harmful to skin and
clothing. To avoid injury or death,
keep away from open fire and use in
well-ventilated area. If pipe thread
sealing compound gets on skin or
clothing, wash immediately with soap
and water.
CAUTION
Use pipe thread sealing compound
sparingly only on pipe threads. Do
not apply compound to hose
connections. Damage to equipment
may result.
(1) Coat threads of tee (1) with pipe thread
sealing compound.
(2) Install fitting (2) on tee (1).
(3) Install tee (1) on engine block (3).
(4) Coat threads of nipple (4), reducer
coupling (5), and elbow (6) with pipe
thread sealing compound.
(5) Install nipple (4), reducer coupling (5), and
elbow (6) on tee (1).
(6) Install clip (7) on upper right thermostat
housing (8) with new lockwasher (9) and
screw (10).
(7) Coat
threads
of
STE/ICE
water
temperature sender (11) with pipe thread
sealing compound.
(8) Install STE/ICE water temperature sender
(11) on fitting (2).
(9) Connect plug (12) to socket (13).
19-17
|