2320-01-318-9902 EIC:B5C, VOLUME NO. 2">
|
|
TM 9-2320-360-20-2
18-10. HEATER REPAIR (CONT)
(4) Install caged nut (9) on stud (10).
(5) Install two retaining dips (11) on blower
wheels (12).
(6) Install two blower wheels (12) in blower
housings (13 and 14).
(7) Install two retaining dips (15) on blower
wheels (12).
NOTE
Blower wheels should turn freely
after installation.
(8) Install foil (16) and blower housing ground
wire (17) on blower housing (13) with new
lockwasher (18) and three screws (19).
(9) Connect blower housing ground wire (17)
to motor wire (20).
(10) Secure electrical connection (17 and 20)
with electrical tape (21).
(11) Position foil (22) on other side of motor
assembly (2).
(12) Install foil (22) on blower housing (14) with
three screws (23).
CAUTION
Use care when installing motor
assembly to avoid damaging fins on
heater core.
(13) Install motor assembly (2) on heater
assembly (24) with two screws (25).
(14) Connect heater wire (26) to speed control
resistor wire (27).
(15) Secure electrical connection (26 and 27)
with electrical tape (21).
18-32
|