17-15. PTO PROPSHAFTS/SUPPORT REPAIR (CONT)
d. Cleaning/inspection
WARNING
Dry cleaning solvent P-D-680 is toxic
and flammable.
Wear protective
goggles and gloves and use only in a
well-ventilated area.  Avoid contact
with skin, eyes, and clothes, and
don't breathe vapors.  DO NOT use
near open flame or excessive heat.
The flash point Is 100-138 F (38-
59 C).  If you become dizzy while
using cleaning solvent, get fresh air
immediately and medical aid.
If
contact with eyes is made, wash your
eyes with water and get medical aid
immediately.
(1) Clean all metal parts with dry cleaning
solvent.
WARNING
Compressed
air
for
cleaning
purposes will not exceed 30 psi (207
kPa).  Use only with effective chip
guarding  and  personal  protective
equipment  (goggles/shield,  gloves,
etc.).
(2) Dry parts with compressed air.
NOTE
Number of balance weights installed
on shafts can vary.
(3) Inspect shafts for damage, bent tubing, or
missing balance weights.
(4) Remove burrs from surfaces where prying
occurred.
(5) Remove foreign material (paint, rust, etc.)
build  up  on  propeller  shafts  and
components.
(6) Inspect yoke (1) for broken, damaged, or
missing teeth.
17-44