TM 9-2320-360-20-2
(20) Check inside door handle (14) operation.
NOTE
Do steps (20) thru (24) to adjust cable
if necessary.
(21) Remove cotter pin (25.2), pin (25.1) and
cable (4) from lock connecting lever (29).
(22) Loosen jam nut (23) and turn clevis end
(24) clockwise on cable (4) to shorten,
counterclockwise to lengthen.
(23) Tighten jam nut (23) and install clevis end
(24) on lock connecting lever (29) with pin
(25.1) and new cotter pin (25.2).
(24) Deleted.
(25) Check operation of inside door handle
(14).
Repeat steps (21) thru (24), if
necessary.
(26) Install spring (30) on door (2) and lock
connecting lever (29).
c. Follow-On Maintenance
Install inner door panel (para 16-26).
Change 1 16-107