2320-01-318-9902 EIC:B5C, VOLUME NO. 2">
|
|
TM 9-2320-360-20-2
11-43. MANIFOLD REPLACEMENT (CONT)
b. Installation
WARNING
Pipe thread sealing compound can
burn easily, can give off harmful
vapors, and Is harmful to skin and
clothing. To avoid Injury or death,
keep away from open fire and use In
well-ventilated area. If pipe thread
sealing compound gets on skin or
clothing, wash Immediately with soap
and water.
CAUTION
Use pipe thread sealing compound
sparingly only on pipe threads. Do
not apply compound at hose
connections. Failure to comply may
result in component damage.
(1) Coat threads of seven fittings (1, 2, 3, 4, 5,
6, and 7), two reducers (8 and 9), two
elbows (10 and 11), and tee (12) with pipe
thread sealing compound.
(2) Install six fittings (1, 2, 3, 4, 5, and 6) on
manifold (13).
(3) Install two reducers (8 and 9) and elbow
(10) on manifold (13).
(4) Install elbow (11) on reducer (8).
(5) Install tee (12) on reducer (9).
(6) Install fitting (7) on elbow (10).
(7) Install manifold (13) on PTO shaft support
(14) with two screws (15), washers (16),
and new locknuts (17).
11-206
|
Privacy Statement - Press Release - Copyright Information. - Contact Us |