2320-01-318-9902 EIC:B5C, VOLUME NO. 2">
|
|
TM 9-2320-360-20-2
(10) Remove coupling (14), coupling (21), elbow
(25), elbow (26), elbow (27), and four reducers
(28) from air manifold (7).
(11) Remove coupling (29), and elbow (30) from
modulator solenoid valve (19).
l. Air Pressure Regulators Adjustment
CAUTION
Windshield washer/city horn air
pressure regulator must be adjusted
to 30 psi (207 kPa). Modulator air
pressure regulator must be adjusted
to 70 psi (483 kPa).
NOTE
Arrows on back of air pressure
regulator point in direction of air flow.
(1) Attach 0-1000 PSI pressure transducer (1) to air
pressure regulator outlet port (2).
(2) Attach air supply hose (3) to air pressure
regulator inlet port (4).
(3) Pull knob (5) to unlock air pressure regulator (6).
(4) Adjust air pressure regulator (6) to proper air
pressure using STE/ICE Test 50 (TM 9-4910-
571-12&P). Turn knob (5) clockwise to increase
regulator pressure or counterclockwise to
decrease regulator pressure.
(5) Push in knob (5) to lock air pressure regulator
(6).
(6) Remove air supply hose (3) and pressure
transducer (1) from air pressure regulator (6).