2320-01-318-9902 EIC:B5C, VOLUME NO. 2">
|
|
TM 9-2320-360-20-2
NOTE
Tag and mark wires and hoses before
removal.
(4) Remove wire no. 1719B (8) and wire no.
1719C (9) from sending unit (10).
(5) Remove hose no. 2661 (11) from elbow (12).
(6) Remove hose no. 2054 (13) from elbow (14).
(7) Remove hose no. 2662 (15) from elbow (16).
(8) Remove two elbows (14 and 16) from valve
(6).
(9) Remove tee (17) from valve (6).
(10) Remove sending unit (10) from elbow (18).
(11) Remove elbow (12) and elbow (18) from tee
(17).
b. Installation
WARNING
Pipe thread sealing compound can burn easily, can give off harmful vapors, and is
harmful to skin and clothing. To avoid injury or death, keep away from open fire
and use in well-ventilated area. If pipe thread sealing compound gets on skin or
clothing, wash immediately with soap and water.
CAUTION
Use pipe thread sealing compound
sparingly only on pipe threads. Do
not apply compound to no. hose
connections. Damage to equipment
may result.
(1) Coat threads of tee (1) and two elbows (2
and 3) with pipe thread sealing compound.
(2) Install tee (1) on valve (4).
(3) Install two elbows (2 and 3) on valve (4).
(4) Coat threads of sending unit (5), elbow
(6), and elbow (7) with pipe thread sealing
compound.
(5) Install elbow (7) and elbow (6) on tee (1).
(6) Install sending unit (5) on elbow (7).