2320-01-318-9902 EIC:B5C, VOLUME NO. 2">
|
|
TM 9-2320-360-20-2
11-19. NO. 1 AIR RESERVOIR AND VALVE REPAIR (CONT)
(3) Remove elbow (7) and elbow (8) from no.
1 air reservoir (4).
(4) Remove elbow (8) and fitting (9) from
check valve (10).
c. Assembly
WARNING
Pipe thread sealing compound can
burn easily, can give off harmful
vapors, and is harmful to skin and
clothing. To avoid injury or death,
keep away from open fire and use in
well-ventilated area. If pipe thread
sealing compound gets on skin or
clothing, wash immediately with soap
and water.
CAUTION
Use pipe thread sealing compound
sparingly only on pipe threads. Do
not apply compound to hose
connections. Damage to equipment
may result.
(1) Coat threads of check valve (1), fittings (2
and 3), five elbows (4, 5 and 6), plug (7),
and drain valve (8) with pipe thread
sealing compound.
(2) Install fitting (2) and three elbows (4) o
n
cross (9).
(3) Install fitting (2), plug (7), and drain valve
(8) on no. 1 air reservoir (10).
11-64
|