2320-01-318-9902 EIC:B5C, VOLUME NO. 2">
|
|
TM 9-2320-360-20-2
11-14. QUICK-RELEASE VALVE REPLACEMENT (CONT)
(13) Remove fitting (10) and tee (14) from
valve (18).
(14) Remove elbow (12) from fitting (27).
(15) Remove fitting (27) from valve (18).
(16) Remove elbow (21), fitting (22), and plug
(28) from valve (25).
b. Installation
WARNING
Pipe thread sealing compound can
burn easily, can give off harmful
vapors, and, is harmful to skin and
clothing. To avoid injury or death,
keep away from open fire and use in
well-ventilated area. If pipe thread
sealing compound gets on skin or
clothing, wash immediately with soap
and water.
CAUTION
Use pipe thread sealing compound
sparingly only on pipe threads. Do
not apply compound to hose
connections. Damage to equipment
may result.
(1) Coat threads of plug (1), elbow (2), and
fitting (3) with pipe thread sealing
compound.
NOTE
To install front gladhand quick-
release valve fittings, do step (2).
(2) Install plug (1), elbow (2), and fitting (3) on
valve (4).
FRONT GLADHAND
11-46
|