8-10. TRANSMISSION AOAP SAMPLING VALVE REPLACEMENT (CONT)
b. Installation
WARNING
Pipe thread sealing compound can
burn easily, can give off harmful
vapors, and Is harmful to skin and
clothing. To avoid Injury or death,
keep away from open fire and use In
well ventilated area. If pipe thread
sealing compound gets on skin or
clothing, wash Immediately with soap
and water.
(1) Coat threads of valve (1) and reducer (2)
with pipe thread sealing compound.
(2) Install reducer (2) on tee (3).
(3) Install valve (1) on reducer (2).
c. Follow-On Maintenance
(1)
Start engine (TM 9-2320-360-10).
(2)
Check for leaks.
(3)
Shut off engine (TM 9-2320-360-10).
(4)
Remove wheel chocks.