b. Disassembly
(1) Remove lockpin (1) and pivot (2) from
control lever assembly (3).
Discard
lockpin.
(2) Loosen nut (4) on actuator (5).
NOTE
Mark position of actuator
before
removal to aid in installation.
(3) Remove lockpin (6) and actuator (5) from
control lever assembly (3).
Discard
lockpin.
(4) Remove nut (4) from actuator (5).
(5) Remove cover plate seal (7) and plastic
cover (8) from control lever assembly (3).
(6) Release two tabs (9) and open cable plug
(10).
(7) Remove wire (11) from hole A in plug (10).
(8) Remove pipe light assembly (12) from
control lever assembly (3).
(9) Remove bulb (13) from pipe light
assembly (12).