2320-01-318-9902 EIC:B5C, VOLUME NO. 2">
|
|
TM 9-2320-360-20-2
(12) Remove push nut (22) from recirculating door
lever (23). Discard push nut.
(13) Remove screw (24) and cable clamp (25)
from upper case (3).
(14) Remove cable assembly (26) from upper
case (3).
NOTE
Do steps (15) thru (17) only if foam
strips fail inspection.
(15) Remove foam strip (27) from recirculating
door (28).
(16) Remove foam strip (29) from upper case (3).
(17) Remove foam strip (30) from upper case (3).
(18) Drill out two rivets (31) and remove
bracket (32) from recirculating door (28).
Discard rivets.
(19) Remove bullet (33) from bracket (32).
(20) Remove foam strip (34) from blower
housing (10).
(21) Remove foam strip (35) from cover (36).
Change 1 7-297
|