7-77. DDEC TERMINAL REPAIR (CONT)
(8) Insert new terminal (7) in locat ing hole of
crimp tool (9) using proper hole according
to the gage of wire (6).
(9) Slide seal (8) down to end of insulation
(10) on wire (6).
NOTE
Wire and seal should be positioned
so larger wings of terminal will crimp
around seal and smaller wings will
crimp around exposed bare wire.
(10) Position wire (6) on terminal (7).
(11) Press handles of terminal crimper (Item 5,
releases and crimp is complete.
(12) Push new terminal (7) and wire (6)
through connector (1) until seated.
(13) Close secondary locks
(3)
on
two
connectors (1 and 2).
(14) Install connector (1) on connector (2).