TM 9-2320-360-20-2
(3) Remove electrical connector (6) from
pressure switch electrical connector (7).
(4) Remove screw (8), lockwasher (9), and
ground wire (10) from power manifold
(11). Discard lockwasher.
(5) Remove pressure switch (12) from power
manifold (11).
b. Installation
WARNING
Pipe thread sealing compound can
bum easily, can give off harmful
vapors, and is harmful to skin and
clothing.  To avoid Injury or death,
keep away from open fire and use in
well-ventilated area.  If pipe thread
sealing compound gets on skin or
clothing, wash immediately with soap
and water.
(1) Coat threads of pressure switch (1) with
pipe thread sealing compound.
(2) Install pressure switch (1) on power
manifold (2).
(3) Install ground wire (3), new lockwasher
(4), and screw (5) on power manifold (2).
(4) Install electrical connector (6) on pressure
switch electrical connector (7).
Change 1 7-221