2320-01-318-9902 EIC:B5C, VOLUME NO. 2">
|
|
TM 9-2320-360-20-2
7-54. BUZZER REPLACEMENT (CONT)
b. Installation
(1) Position buzzer (1 or 2) on instrument
panel (3).
(2) Install knurled nut (4) on buzzer (1 or 2).,
NOTE
Do step (3) only if wire connections
are pronged.
(3) Connect wire no. 1276 (5) to positive (+)
terminal (6) and wire no. 1120 (7) to
negative (-) terminal (8) of buzzer (2).
(4) Install wire no. 439 (9) and screw (10) on
positive (+) terminal (11) of buzzer (1).
(5) Install wire no. 509 (12) and screw (13) on
negative (-) terminal (14) of buzzer (1).
c. Follow-On Maintenance
Install instrument panel (para 7-13).