b. Installation
(1) Install new gasket (1) over wires and
position on strobe light base (2).
WARNING
On direct contact, uncured silicone
sealant irritates eyes.
In case of
contact, flush eyes with water and
seek medical attention. In case of
skin contact, wipe off and flush with
water.
(2) Apply silicone adhesive-sealant around
wires where they pass thru new gasket
(1).
(3) Install strobe light assembly (3) and new
gasket (1) on mounting bracket (4) with
three screws (5) and new locknuts (6).
(4) Install mounting bracket (4) on cab (7)
with three new lockwashers (8) and
screws (9).
(5) Install plug (10) in connector (11).
c. Follow-On Maintenance
(1) Check
light
operation
(TM
9-2320-360-10).
(2) Remove wheel chocks.