2320-01-318-9902 EIC:B5C, VOLUME NO. 2">
|
|
TM 9-2320-360-20-2
7-37. MAGNETIC SWITCH REPLACEMENT (CONT)
(6) Remove two screws (18) and magnetic
switch (19) from electronic control box
assembly (3).
h. R13 Relay Installation
(1) Install magnetic switch (1) in electronic
control box assembly (2) with two screws
(3).
(2) Install wire no. 1075 (4), wire no. 1107
(5), wire no. 1109 (6), and nut (7) on
terminal (8).
(3) Install wire no. 1175 (9) and nut (10) on
terminal (11).
(4) Install wire no. 1189 (12) and nut (13) on
terminal (14).
(5) Install two wires no.
1435 (15) and nut
(16) on terminal (17).
7-110 Change 1
|