7-37. MAGNETIC SWITCH REPLACEMENT (CONT)
(6) Remove two screws (18) and switch (19)
from electronic control box assembly (3).
f. R31 Relay Installation
(1) Install magnetic switch (1) in electronic
control box assembly (2) with two screws
(3).
(2) Install wire no. 1430 (4), wire no. 1402
(5), wire no. 1075 (6), and nut (7) on
terminal (8).
(3) Install wire no. 1075A (9) and nut (10) on
terminal (11).
(4) Install wire no. 1072 (12) and nut (13) on
terminal (14).
(5) Install two wires no.
1435 (15) and nut
(16) on terminal (17).