TM 9-2320-360-20-2
7-19. RHEOSTAT SWITCH REPLACEMENT
This task covers:
a. Removal
c.
Follow-O n Maintenance
b. Installation
INITIAL SETUP
Equipment Conditions
Materials/Parts
Instrument panel removed (para 7-13).
Lockwasher (Item 98, Appendix G)
Nuts (2) (Item 126, Appendix G)
Tools and Special Tools
Tool Kit, Genl Mech (Item 54, Appendix F)
a. Removal
(1) Remove wire no. 1084 (1) from BAT
terminal (2).
(2) Remove nut (3), lockwasher (4), arid two
wires no. 1052 (5) from rheostat switch
(6). Discard lockwasher.
(3) Remove two nuts (7), screws (8), spacers
(9) and rheostat (6) from instrument panel
(10). Discard nuts.