2320-01-318-9902 EIC:B5C, VOLUME NO. 2">
|
|
TM 9-2320-360-20-2
6-13. FAN CONTROL VALVE REPLACEMENT
This task covers:
a. Removal
c.
Follow-On Maintenance
b. Installation
INITIAL SETUP
Equipment Conditions
Materials/Parts
Cooling system drained (para 6-2).
Compound, Sealing, Pipe Thread (Item 15,
Tags, Identification (Item 32, Appendix C)
Tools and Special Tools
Tool Kit, Genl Mech (Item 54, Appendix F)
a. Removal
NOTE
Tag and mark air lines and fittings
before removal.
(1) Remove air line no. 2758 (1) from elbow
(2).
(2) Remove air line no. 2759 (3) from elbow
(4).
(3) Remove elbow (2) from fan control valve
(5).
(4) Turn
fan
control
valve
(5)
counterclockwise until elbow (4) faces
down.
(5) Remove elbow (4) from fan control valve
(5).
(6) Remove fan control valve (5) from left
thermostat housing (6).
6-59
|