TM 9-2320-360-20-2
4-3. AIR CLEANER ASSEMBLY REPAIR (CONT)
(5) Remove elbow (13) from air cleaner (6).
(6) Remove STE/ICE sensor (14), fitting (15),
tee (16), reducer (17), and nipple (18)
from air cleaner (6).
(7) Remove four locknuts (19), screws (20),
and two mounting rails (21) from air
cleaner (6).
Discard locknuts.
(8) Remove clamp (22) and dust cup (23)
from air cleaner (6).
(9) Remove two locknuts (24), lockwashers
(25), screws (26), and mounting brackets
(27) from air cleaner (6). Discard locknuts
and lockwashers.
c. Assembly
(1) Install two mounting brackets (1) on air
cleaner (2) with two screws (3), new
lockwashers (4), and new locknuts (5).
(2) Install dust cup (6) on air cleaner (2) with
clamp (7).
(3) Install two mounting rails (8) on air cleaner
(2) with four screws (9) and new locknuts
(10).
4-6
|