TM 9-2320-285-24-2
4-4. TRANSMISSION (CONT)
c. Forward Clutch and Shaft Assembly (cont).
STEP
LOCATION
ITEM
ACTION
REMARKS
DISASSEMBLY (cont)
4
Turbine
a. Lip type ring
Remove
Return turbine shaft and
shaft and
(23)
clutch housing assembly (17)
clutch
to work table. Discard lip
housing
type ring (23)
assembly
b. Two check balls
Remove
Only if inspection shows re-
(17)
(24)
placement is necessary.
Remove staked metal from
bores to free check balls
(24)
c. Pin (25)
Remove
Depress valve plug (26)
d. Valve plug (26)
Remove
and valve
spring (27)
e. Centrifugal
Remove
valve (28)
CLEANING
WARNING'
Dry cleaning solvent (P-D-680), used to clean parts is toxic and flammable. Wear protective goggles and gloves and
use only in a well ventilated area. Avoid contact with skin, eyes, and clothes and don't breathe vapors. Do not use
near open flame or excessive heat and don't smoke when using it. Failure to do so could cause serious injury. If
you become dizzy while using cleaning solvent, get fresh air immediately, and get medical attention. If contact with
skin or clothes is made, flush with large amounts of water. If contact with eyes is made, wash eyes with water
immediately, and obtain medical aid immediately.
WARNING
Compressed air must not exceed 30 psi. Wear safety glasses when drying parts with compressed air. Failure to do
so could cause serious injury to eyes and possible blindness. If you hurt your eyes or if a foreign object is blown into
your eyes, seek medical attention immediately.