TM 9-2320-285-24-2
4-4.
TRANSMISSION (CONT)
b.
Main Shaft and Gear Unit Assembly (cont).
STEP
LOCATION
ITEM
ACTION
REMARKS
CLEANING
WARNING
Dry cleaning solvent (P-D-680), used to clean parts is toxic and
flammable. Wear protective goggles and gloves and use only in a well
ventilated area. Avoid contact with skin, eyes, and clothes and don't
breathe vapors. Do not use near open flame or excessive heat and don't
smoke when using it. Failure to do so could cause serious injury. If you
become dizzy while using cleaning solvent, get fresh air immediately, and
get medical attention. If contact with skin or clothes is made, flush with
large amounts of water. If contact with eyes is made, wash eyes with
water immediately, and obtain medical aid immediately.
Compressed air must not exceed 30 psi. Wear safety glasses when
drying parts with compressed air. Failure to do so could cause serious
injury to eyes and possible blindness. If you hurt your eyes or if a foreign
object is blown into your eyes, seek medical attention immediately.
12
All parts
Clean
Use cleaning solvent P-D-680.
Immerse parts in solvent and
move up and down to remove
all dirt and old lubricant.
Dry thoroughly with clean,
dry, lintless cloths or with
compressed air. Don't use
compressed air to dry bear-
ing assembly (14) and
rollers (35, 41, and 46)
INSPECTION
13
a
Front, center,
Inspect
Inspect for worn, overheated,
and rear
or contaminated condition.
planetary
Inspect rollers (35, 41, and
carrier
46) for roughness and bind-
assemblies
ing in operation
Check
end
(6, 18, and
play of pinion sets (28, 34,
26)
and 40) by inserting thick-
4-29
|