3-38. HEATER MAINTENANCE (CONT)
STEP
LOCATION
ITEM
ACTION
REMARKS
REASSEMBLY (cont)
8
Motor (14)
a. Plate (8) with
Position
On motor (14)
new gasket (9)
b. Two nuts (6)
Install
Tighten nuts (6) evenly
and washers
(7)
c. Setscrew (4)
Install
If removed
d. Blower wheel
Position
Align setscrew with flat on
(5)
motor shaft
e. Setscrew (4)
Tighten
f. Plate (8) with
Position
motor (14)
g. Four screws
Install and
(3)
tighten
h. Two clamps (1)
Position
Open with hose clamp pliers
and slide to center of hose
(2)
i. Hose (2) with
Install
clamps (1)
j. Two clamps (1)
Install
Loosen with hose clamp pliers
and slide to ends of hose
NOTE
Perform following steps only if necessary to install wire connectors (10) or connector shell (11).
k. Electrical
Strip 1/4 inch insulation from ends
leads (12
and 13)
l. New wire con-
a. Install on
Crimp securely
nectors (10)wires
b. Push into
As tagged in step 1 above
connector
shell
(11)