TM 9-2320-285-24-2
3-25.
AIR COMPRESSOR ASSEMBLY MAINTENANCE
b. Air Compressor Assembly (cont).
STEP
LOCATION
ITEM
ACTION
REMARKS
DISASSEMBLY (cont)
7
j.
Front bearing
Remove
(cont)
(20)
k.
Crankshaft (49) Press out
CLEANING
WARNING
Dry cleaning solvent (P-D-680), used to clean parts is toxic and flammable. Wear protective goggles and gloves and
use only in a well ventilated area. Avoid contact with skin, eyes, and clothes and don't breathe vapors. Do not use
near open flame or excessive heat and don't smoke when using it. Failure to do so could cause serious injury. If you
become dizzy while using cleaning solvent, get fresh air and medical attention immediately. If contact with skin or
clothes is made, flush with large amounts of water. If contact with eyes is made, wash eyes with water and seek
medical aid immediately.
Compressed air must not exceed 30 psi. Wear safety glasses when drying parts with compressed air. Failure to do
so could cause serious injury to eyes and possible blindness. If you hurt your eyes or if a foreign object is blown into
your eyes, seek medical attention immediately.
8
a.
All parts
Clean
Use cleaning solvent P-D-680
and stiff bristled brush;
dry with compressed air
b.
Cylinder head
Clean
Remove all carbon deposits
(4)
from discharge cavities.
Remove rust and scale from
cooling cavities. Scrape
all foreign matter from all
surfaces. Use shop air to
clear all cavities
c.
Crankcase (18)
Clean
Remove all carbon deposits
from inlet and unloader
passages. Use shop air to
clear unloader passages and
oil passages. Run wire
through oil passages
3-217
|