3-24.
BRAKE CONTROLS MAINTENANCE (CONT)
f.
Ratio Reducing Valve (cont).
STEP
LOCATION
ITEM
ACTION
REMARKS
CLEANING
WARNING
Dry cleaning solvent (P-D-680), used to clean parts is toxic and
flammable. Wear protective goggles and gloves and use only in a well
ventilated area. Avoid contact with skin, eyes, and clothes and don't
breathe vapors. Do not use near open flame or excessive heat and
don't smoke when using it. Failure to do so could cause serious injury.
If you become dizzy while using cleaning solvent, get fresh air and
medical attention immediately. If contact with skin or clothes is made,
flush with large amounts of water. If contact with eyes is made, wash
eyes with water and obtain medical aid immediately.
Compressed air must not exceed 30 psi. Wear safety glasses when
drying parts with compressed air. Failure to do so could cause serious
injury to eyes and possible blindness. If you hurt your eyes or if a
foreign object is blown into your eyes, seek medical attention
immediately.
3
All parts
Clean
Use cleaning solvent P-D-680
and stiff bristle brush;
dry thoroughly with
compressed air
INSPECTION
4
a
Spring (14)
Inspect
Replace if cracked or
permanently set
b
All other parts
Inspect
Replace if cracked, broken,
or threads damaged
REASSEMBLY
NOTE
Use new items 7, 8, 9, 11, 12, and 13 included in ratio reducing valve
maintenance kit.