13-12. WIRING HARNESS MAINTENANCE (CONT)
d. Engine Harness (cont).
STEP
LOCATION
ITEM
ACTION
REMARKS
INSTALLATION (cont)
11
b
Water tempera-
Connect
Green/black lead; para 2-32c
(cont)
ture sender
electrical
lead
c
Alarmstat elec-
Connect
Violet lead; para 2-32c
trical lead
d
Oil pressure
Connect
Para 2-32a
sender and
sensor elec-
trical leads
e
Connect
Red and tan/green leads; para
70A circuit
2-25a
breaker elec-
trical leads
f
Connect
Para Z-24
electrical
leads
g
Connect
White, gray, and gray/black
der electri-
leads; para 2-86
cal leads
h
Water level
Connect
Para 2-29
sensor elec-
trical leads
i
Ether valve
Connect
Para 2-13d
electrical
leads
j
Engine stop
Connect
As tagged
electrical
leads
k
Transmission
Connect
Para 2-32d
temperature
sender elec-
trical leads
l
White ground
Install and
On left hand thermostat
lead, lock
tighten
housing at location noted
washer, and
during removal
capscrew
12
Right hand
a
Two horn relay
Connect
Para 2-33a
frame rail
electrical
leads
3-87