TM 9-2320-285-24-2
3-9. ALTERNATOR MAINTENANCE (CONT)
STEP
LOCATION
ITEM
ACTION
REMARKS
DISASSEMBLY (cont)
5
Housing (8)
a.
Two screws
Remove
(25), washers
(26), and
(27)
b.
Two field coil
Disconnect
From regulator (28)
(21) leads
c.
Screw (23) and
Remove
washer (63)
d.
Diode trio (55)
Remove
and regulator
(28)
6
Output
a.
Screw (29) and
Remove
terminal
lock washer
connector
(30)
(39)
b.
Capacitor (58)
Disconnect
Move aside
lead
c.
Nuts (32 and
Loosen
35)
d.
Output terminal
Remove
connector
assembly
(32 thru 39,
65, and 66)
e.
Nut (32), wash-
Remove, if
From output terminal
ers (33 and
necessary
connector (39)
34), nut
(35), washers
(36, 37, and
38), insula-
tor (64), and
bolt (65)
7
Rectifier
a.
Two screws
Remove
bridge
(52), washers
(53)
(66), and
washers (31)
b.
Rectifier
Remove
bridge (53)
c.
Insulator (54)
Remove
3-39
|