TM 9-2320-285-24-1
2-87.
PRESSURE GAGES MAINTENANCE
b.
AIR PRESSURE Gage (cont).
STEP
LOCATION
ITEM
ACTION
REMARKS
REMOVAL (cont)
4
b. Tubing nut (10)
Loosen
(cont)
c. Tubing (3)
Disconnect
From connector (11)
d. Tubing nut (10)
Remove
From tubing (3) only if
tubing is to be replaced
e. Tubing (3)
Remove
From tractor
f. Connector (11)
Remove
From tee (12)
g. Tee (12)
Remove
CLEANING
5
a. Tubing (3) and
Clean
Wipe with clean, dry cloth
air pressure
gage (7)
WARNING
Dry cleaning solvent (P-D-680), used to clean parts is toxic and flammable. Wear
protective goggles and gloves and use only in a well ventilated area. Avoid contact with
skin, eyes, and clothes and don't breathe vapors. Do not use near open flame or
excessive heat and don't smoke when using it. Failure to do so could cause serious
injury. If you become dizzy while using cleaning solvent, get fresh air and medical
attention immediately.
If contact with skin or clothes is made, flush with large amounts of water. If contact with
eyes is made, wash eyes with water and seek medical aid immediately.
b. All other parts
Clean
Use cleaning solvent P-D-680;
dry with clean cloths
INSPECTION
6
a. Tubing (3)
Inspect
Replace if cut, cracked, or
deteriorated
b. Air pressure
Inspect
Replace if cracked, broken,
gage (7)
leaking, or inoperative
c. All other parts
Inspect
Replace if cracked, broken,
or threads damaged
2-927
|
Privacy Statement - Press Release - Copyright Information. - Contact Us |