TM 9-2320-285-24-1
2-87.
PRESSURE GAGES MAINTENANCE
a.
OIL PRESSURE Gage (cont).
STEP
LOCATION
ITEM
ACTION
REMARKS
REMOVAL
NOTE
Tag and identify all electrical leads before disconnecting and removing.
1
Instrument
a. Two electrical
Tag
panel,
leads
underside
(3 and 4)
b. Two nuts (1)
Remove
and lock
washers (2)
c. Two electrical
Disconnect
leads
(3 and 4)
d. Two nuts (5)
Remove
and lock
washers (6)
e. Mounting clamp
Remove
(7)
2
Instrument
Oil pressure gage
Remove
Lift from instrument panel
panel, top(8)
CLEANING
3
a. Oil pressure
Clean
Wipe with clean, dry cloth
gage (8) and
leads (3 and
4)
WARNING
Dry cleaning solvent (P-D-680), used to clean parts is toxic and flammable. Wear protective
goggles and gloves and use only in a well ventilated area. Avoid contact with skin, eyes, and
clothes and don't breathe vapors. Do not use near open flame or excessive heat and don't
smoke when using it. Failure to do so could cause serious injury. If you become dizzy while
using cleaning solvent, get fresh air and medical attention immediately. If contact with skin or
clothes is made, flush with large amounts of water. If contact with eyes is made, wash eyes
with water and seek medical aid immediately.
2-923
|