TM 9-2320-285-24-1
2-73. HEATERS MAINTENANCE (CONT)
f.
Junction Box (cont).
STEP
LOCATION
ITEM
ACTION
REMARKS
TESTING
8
Junction
a. Ohmmeter with
a. Set to X1 range
box (20)
test leads
b. Connect one lead to L-shaped prong of
connector insert (8)
c. Connect remaining lead to either straight
prong of connector insert
d. Note ohmmeter reading. Ohmmeter must
indicate open circuit (infinity)
e. Disconnect ohmmeter lead from straight
prong and connect to remaining straight
prong
f. Note ohmmeter reading. Ohmmeter must
indicate open circuit (infinity)
g. Disconnect ohmmeter leads from connector
insert (8)
WARNING
If ohmmeter indicates continuity in either test above, check for short
circuit or incorrect wiring. Do not apply power to connector insert (8) until
problem is corrected to prevent severe electrical shock.
b. Door (1)
Install
Slide up
c. Latch (15)
Rotate under
Secures door (1)
door (1)
2-856
|