 |  TM 9-2320-285-24-1 2-73. HEATERS MAINTENANCE (CONT) f. Junction Box (cont). STEP LOCATION ITEM ACTION REMARKS TESTING 8 Junction a. Ohmmeter with a. Set to X1 range box (20) test leads b. Connect one lead to L-shaped prong of connector insert (8) c.  Connect remaining lead to either straight prong of connector insert d. Note ohmmeter reading. Ohmmeter must indicate open circuit (infinity) e. Disconnect ohmmeter lead from straight prong and connect to remaining straight prong f.  Note ohmmeter reading. Ohmmeter must indicate open circuit (infinity) g. Disconnect ohmmeter leads from connector insert (8) WARNING If ohmmeter indicates continuity in either test above, check for short circuit or incorrect wiring. Do not apply power to connector insert (8) until problem is corrected to prevent severe electrical shock. b. Door (1) Install Slide up c.  Latch (15) Rotate under Secures door (1) door (1) 2-856 | 