2-73.
HEATERS MAINTENANCE (CONT)
a.
Cab Heater, Hoses, and Temperature Valve (cont).
STEP
LOCATION
ITEM
ACTION
REMARKS
REMOVAL (cont)
9
f. Two capscrews
Remove
(cont)
(28), seal
plate (29),
and bracket
(30)
g. Heater (27)
Remove
From cab
CLEANING
10
a. All hoses
Clean
Use clean cloth and mild
detergent solution
b. Heater (27)
a. Clean
Wipe exterior of motor with
clean, dry cloth. Clean
remainder of exterior with
clean cloth and mild
detergent solution
b. Flush
Connect water supply to hose
ports and flush core; then
reverse connection and
flush in opposite direction
until water is clear
WARNING
Dry cleaning solvent (P-D-680), used to clean parts is toxic and
flammable. Wear protective goggles and gloves and use only in a well
ventilated area. Avoid contact with skin, eyes, and clothes and don't
breathe vapors. Do not use near open flame or excessive heat and don't
smoke when using it. Failure to do so could cause serious injury. If you
become dizzy while using cleaning solvent, get fresh air and medical
attention immediately. If contact with skin or clothes is made, flush with
large amounts of water. If contact with eyes is made, wash eyes with
water and seek medical aid immediately.
c. All other parts Clean
Use cleaning solvent P-D-680;
dry with clean cloths
2-817

Privacy Statement - Press Release - Copyright Information. - Contact Us

Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business