TM 9-2320-285-24-1
2-68.
HEATERS TROUBLESHOOTING (CONT)
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
5.
BATTERIES NOT WARMED WHEN BATTERY WARMERS CONNECTED TO POWER SOURCE (Cont)
Step 2.
Connect power cord between junction box and 110 Vac outlet.
Check if both battery warmers are cold.
WARNING
Battery warmers operate from 110 Vac power source. Disconnect winterization system cable
from receptacle at front bumper of tractor before proceeding. Serious injury or death can
result from contact with energized 110 Vac power lines.
Disconnect power cord from junction box and 110 Vac outlet.
a.
If both battery warmers are cold, go to step 4 below.
b.
If only one battery warmer is cold, go to step 3 below.
Step 3.
Check for loose connection at wire nuts connecting battery warmer 3-wire cord to 3-wire cord from
junction box.
a.
If connection is loose, reconnect (para 2-73c).
b. If connection is not loose, replace battery warmer (para 2-73c).
Step 4.
Use an ohmmeter to check continuity of 3-wire cord between battery warmers and junction box.
a.
If continuity is not obtained, replace 3-wire cord (para 2-73c).
b.
If continuity is obtained, replace battery warmers (para 2-73c).
6.
COOLANT NOT WARMED WHEN COOLANT HEATER CONNECTED TO POWER SOURCE
Step 1.
Check if engine oil heater and battery warmers are not operating (engine oil heater and battery warmers
cold to the touch).
a.
If engine oil heater and battery warmers are not operating, go to Malfunction 8 below.
b.
If engine oil heater or battery warmers are operating, go to step 2 below.
2-766
|