TM 9-2320-285-24-1
2-65. BODY AND CAB MAINTENANCE (CONT)
g. Radiator Access Panel (cont).
STEP
LOCATION
ITEM
ACTION
REMARKS
INSPECTION (cont)
3
WARNING
(cont)
Compressed air must not exceed 30 psi. Wear safety glasses when drying parts with
compressed air. Failure to do so could cause serious injury to eyes and possible
blindness. If you hurt your eyes or if a foreign object is blown into your eyes, seek
medical attention immediately.
c. Self-adhesive
Inspect for:
Replace if defective. Use
rubber
cracks
sharp edged object and
strips (10)
gouges
scrape strip from hood
breaks
enclosure. Clean area using
cleaning solvent P-D-680
and dry using compressed
air
d. All other
Inspect for:
Replace if defective
parts
damaged
threads
deformation
INSTALLATION/REPLACEMENT
4
Hood
a. New self-
Install if
Peel paper backing off a
enclosure,
adhesive
removed
strip cut 8 inches long.
top
rubber
Place alongside edge of
strips (10)
radiator access hole and
press down
b. Radiator access Position
plate (9)
c. Two capscrews
Install
(6), washers
(8), and
locknuts (7)
d. Latch (4) and
Install on
three washers
screw (1)
(5)
e. Screw (1),
Install
washer (3),
and nut (2)
f. Radiator access
Close
plate (9)
g. Latch (4)
Position
Over radiator access plate
(9)
2-731
|