TM 9-2320285-24-1
2-51.
AIR BRAKE SYSTEM MAINTENANCE (CONT)
a. Air Brake Lines and Fittings (cont).
STEP
LOCATION
ITEM
ACTION
REMARKS
REPAIR (cont)
NOTE
Repeat steps 19e thru 19j above to install remaining fittings on tubing.
20
Hoses
a. Connector
Turn counterclockwise out of nut and hose
b. Nut
Turn clockwise and remove from hose
NOTE
Repeat steps 20a and 20b above to disassemble remaining connectors from hoses.
WARNING
Dry cleaning solvent (P-D-680), used to clean parts is toxic and flammable. Wear protective goggles and
gloves and use only in a well ventilated area. Avoid contact with skin, eyes, and clothes and don't breathe
vapors. Do not use near open flame or excessive heat and don't smoke when using it. Failure to do so
could cause serious injury. If you become dizzy while using cleaning solvent, get fresh air and medical
attention immediately. If contact with skin or clothes is made, flush with large amounts of water. If contact
with eyes is made, wash eyes with water and seek medical aid immediately.
c. Connector and
Clean
Use cleaning solvent P-D-680;
nut
allow to air dry. Use wire
brush to remove all hose
residue from connector and
nut
d. Hose
Cut to proper
Use new hose; use old hose to
length
determine proper length
required. Cut hose square
using fine tooth hacksaw
e. Nut
Screw counterclockwise
onto hose until hose
bottoms
f. Connector
Screw clockwise into nut
and hose and
tighten securely
2-566
|