Click here to make tpub.com your Home Page

Page Title: CLEANING
Back | Up | Next

Click here for thousands of PDF manuals

Google


Web
www.tpub.com

Home


   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Logistics
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
   
   

 

TM 9-2320-285-24-1
2-35.
WIRING HARNESS MAINTENANCE (CONT)
c.
Instrument Panel Harnesses (cont).
(2)
Right Corner Panel Harness (cont).
STEP
LOCATION
ITEM
ACTION
REMARKS
CLEANING
1
a. Right corner
Clean
Wipe with a clean, dry cloth
panel harness
where wiring is accessible
(3)
WARNING
Dry cleaning solvent (P-D-680), used to clean parts is toxic and flammable. Wear protective
goggles and gloves and use only in a well ventilated area. Avoid contact with skin, eyes, and
clothes and don't breathe vapors. Do not use near open flame or excessive heat and don't
smoke when using it. Failure to do so could cause serious injury. If you become dizzy while
using cleaning solvent, get fresh air and medical attention immediately. If contact with skin or
clothes is made, flush with large amounts of water. If contact with eyes is made, wash eyes
with water and seek medical aid immediately.
b. Connectors
Clean
Use clean cloth moistened
(1 and 2)
with cleaning solvent
P-D-680; dry with clean
cloths
INSPECTION/REPAIR
2
a. Connectors
a. Tag
(1 and 2)
b. Disconnect
c. Inspect
Replace right corner panel
harness (3) if connector
bent or damaged (notify
direct support maintenance)
NOTE
Gage of replacement wire must be greater than or equal to gage of defective wire.
2-404

Privacy Statement - Press Release - Copyright Information. - Contact Us

Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business