TM 9-2320-285-24-1
2-35.
WIRING HARNESS MAINTENANCE (CONT)
a.
Cab Harnesses (cont).
(2)
Lower Cab Harness (cont).
STEP
LOCATION
ITEM
ACTION
REMARKS
INSPECTION/REPAIR (cont)
2
f. Lower cab
Inspect
Repair if insulation frayed
(cont)
harness (4)
or conductor broken. Wrap
electrical tape over frayed
insulation. If broken
conductor is accessible,
cut a length of same gage
wire and splice using in-
sulated splice connector;
if wire is not accessible,
replace harness (notify
direct support maintenance)
TESTING
3
Cab
Lower cab harness
Test
Use multimeter set to X1 ohms
(4)
range (refer to electrical
system wiring schematic);
refer to step (2) above for
repair of broken conductor
4
Cab,
a.
Connector (3)
Connect
As tagged, para 2-73a
inside
b.
Connector (2)
Connect
As tagged, para 2-26a(5)
c.
Connector (1)
Connect
As tagged, para 2-35c(1)
d.
Instrument
Lower and
panel
secure
5
Battery
Battery ground
Connect
box
cable
6
Cab
a. Key switch
Turn on
b. Lights,
Check
If lights, controls, or
controls, and
operation
indicators do not operate,
indicators
procedures
c. Key switch
Turn off
2-393
|