TM 9-2320-285-24-1
2-34.
BATTERY SYSTEM MAINTENANCE
a.
Battery Cables and Batteries (cont).
STEP
LOCATION
ITEM
ACTION
REMARKS
INSPECTION (cont)
8
c.
Rubber pads
Inspect
Replace if cracked, torn, or
(cont)
(16)
deteriorated
d. All other parts
Inspect
Replace if cracked, broken,
distorted, or threads
damaged
TESTING
WARNING
Battery electrolyte is toxic and corrosive. Use protective goggles and gloves when performing
the following. Avoid contact with skin, eyes, clothes, and don't breathe vapors. Failure to
follow this procedure could cause severe injury. If you are injured, obtain medical aid
immediately.
9
Batteries
a. Vent covers
Remove
(15)
b. Specific
Check
Use hydrometer. Draw suffic-
ient electrolyte into
hydrometer to allow float
to suspend freely. Note the
reading of float at liquid
level as shown. Return
electrolyte to battery cell
by squeezing hydrometer
bulb
For convenience, hydrometer scale may be marked 1270,
1280, etc., instead of 1.270, 1.280, etc.
2-380
|