TM 9-2320-285-24-1
2-31.
LIGHT SYSTEMS M AINTENANCE (CONT)
g. Flood Lights (cont).
STEP
LOCATION
ITEM
ACTION
REMARKS
INSTALLATION (REAR FLOOD LIGHT) (cont)
6
CAUTION
(cont)
In following step, don't overtighten screws; to do so
will cause damage to lens (21).
h. Four screws
Install and
(20)
tighten
INSTALLATION (ROOF FLOOD LIGHTS)
7
Tractor cab
a. Grommet (19)
Install
If necessary
roof
b. Loom (18)
Install
On wire lead (17)
c. Wire lead (17)
Route
Through grommet (19)
and loom (18)
d. Bracket (14)
Position
On cab roof as noted during
removal
e. Capscrew (13),
Install and
lock washer
tighten
(12) and nut
(11)
f. Housing (10)
Position
On bracket (14)
g. Capscrew (7),
Install and
lock washer
tighten
(9), and nut
(8)
h. Spacer (6) and
Position
gasket (5)
i. Connector (3)
Connect
To sealed beam (4)
j. Sealed beam (4)
Install
k. Ring (2)
Install
l. Capscrew (1)
Install and
tighten
8
Cab
a. Wire leads (16
Strip insulation 3/8 inch from ends of
interior
and 17)
wire leads
b. Crimp connector
Install on wire leads then crimp securely
(15)
c. Head liner
Glue
Into position
NOTE
Place flood light switches in ON positions and check that flood lights operate properly.
2-341
|
Privacy Statement - Press Release - Copyright Information. - Contact Us |