TM 9-2320-285-24-1
2-31. LIGHT SYSTEMS MAINTENANCE (CONT)
c. Cab Interior Light (cont).
STEP
LOCATION
ITEM
ACTION
REMARKS
CLEANING (cont)
2
c. Screws (3)
Clean
Use cleaning solvent P-D-680;
(cont)
dry with compressed air or
clean cloths
INSPECTION
3
a. Lamp (2)
Inspect
Replace if burned out or
filament broken
b. All other parts
Inspect
Replace if cracked, broken,
or threads damaged
INSTALLATION
4
Cab,
a. Electrical
Strip
Strip 1/4 inch of insulation
inside,
leads (6 and
from wire ends
left hand
7)
side,
b. New wire
Install
Crimp onto electrical leads
above door
connector (4)
(6 and 7)
c. Light housing
Position
(5)
d. Four screws (3)
Install and
tighten
e. Cover (1)
Install
Press onto light housing (5)
2-325
|