TM 9-2320-285-24-1
2-26. INSTRUMENT PANEL MAINTENANCE (CONT)
c.
Water Level Warning Bell and Low Air Pressure Buzzer (cont).
(1) Water Level Warning Bell (cont).
STEP
LOCATION
ITEM
ACTION
REMARKS
REMOVAL
NOTE
Tag and identify all electrical leads before disconnecting and removing.
1
Right
a. Two electrical
Tag
instrument
leads (7 and
panel
8)
b. Three locknuts
Remove
While assistant above panel
(1) and lock
prevents screws (3) from
washers (2)
rotating
c. Three screws
Remove
(3)
d. Warning bell
Remove
(4) and
gasket (5)
e. Two screws (6)
Remove
f. Two electrical
Disconnect
leads
(7 and 8)
CLEANING
2
All parts
Clean
Wipe with clean, dry cloth
INSPECTION
3
a. Two electrical
Inspect
Replace if insulation frayed
leads
or connectors damaged
(7 and 8)
b. Warning bell
Inspect
Replace if cracked or broken
(4)
c. All other parts Inspect
Replace if cracked, broken,
distorted, or threads
damaged
2-259
|